Definition:

A firefighting system in tunneling and underground structures refers to a comprehensive set of equipment, devices, and protocols designed to detect, control, and extinguish fires in tunnels and underground spaces. It includes various components such as fire detection systems, fire suppression systems, emergency communication systems, and fire safety equipment.

Uses/benefits:

  • Fire Prevention and Safety: The primary purpose of a firefighting system is to prevent and mitigate the risks associated with fires in tunneling and underground structures. It helps ensure the safety of personnel, protect critical infrastructure, and minimize damage to property.
  • Early Fire Detection: Fire detection systems, including smoke detectors, heat detectors, and flame detectors, are installed throughout the tunnel to detect the presence of fire at its early stages. Early detection enables prompt response and intervention, reducing the spread of fire and allowing for effective evacuation procedures.
  • Fire Suppression: Firefighting systems incorporate various fire suppression methods, such as water-based systems, foam systems, and gas-based systems. These systems are designed to quickly suppress and extinguish fires by reducing heat, oxygen, or fuel sources.
  • Emergency Communication: Firefighting systems include communication systems, such as public address systems, emergency phones, and fire alarm systems, to alert occupants and facilitate rapid evacuation during a fire emergency. These systems help ensure effective communication and coordination among personnel and emergency responders.
  • Evacuation and Escape Routes: Firefighting systems include provisions for well-designed evacuation routes, emergency exits, and escape staircases. These routes are clearly marked and equipped with emergency lighting to aid safe evacuation in the event of a fire.

Specifications:

  • Fire Detection Systems: Firefighting systems employ various types of fire detection systems, including smoke detectors, heat detectors, flame detectors, and video surveillance systems. These systems are strategically placed throughout the tunnel to provide comprehensive coverage.
  • Fire Suppression Systems: Different types of fire suppression systems are used, depending on the nature of the fire and the specific requirements of the tunnel. These systems may include water-based systems, such as sprinklers and deluge systems, foam systems, and gas-based systems like carbon dioxide (CO2) or inert gas systems.
  • Emergency Communication Systems: Firefighting systems incorporate emergency communication systems to enable rapid communication between occupants, tunnel operators, and emergency responders. These systems may include public address systems, emergency phones, and fire alarm systems with voice evacuation capabilities.
  • Fire Safety Equipment: Firefighting systems involve the provision of fire safety equipment, including fire extinguishers, fire blankets, fire hoses, and fire hydrants. These equipment items are strategically placed for quick access and use in case of small fires or as additional measures during emergencies.

Types:

  • Wet Pipe Systems: Wet pipe fire suppression systems use water as the primary extinguishing agent. Water is stored in pipes and released through sprinkler heads or nozzles when activated by a fire detection system.
  • Dry Pipe Systems: Dry pipe fire suppression systems are typically used in areas prone to freezing temperatures. These systems store pressurized air or nitrogen in the pipes, which is released to expel water once the fire detection system is activated.
  • Pre-action Systems: Pre-action fire suppression systems are a combination of wet and dry pipe systems. These systems require two triggers, typically a fire detection signal and a sprinkler head activation, to release water.
  • Foam Systems: Foam-based fire suppression systems use foam concentrate mixed with water to form a foam solution that is discharged onto the fire. Foam systems are effective in combating flammable liquid fires.
  • Gas-based Systems: Gas-based fire suppression systems use gases, such as carbon dioxide (CO2), inert gases (e.g., nitrogen or argon), or clean agents (e.g., FM-200 or Novec 1230), to suppress fires by reducing the oxygen concentration or interrupting the chemical chain reaction.

The selection and design of firefighting systems for tunneling and underground structures depend on various factors, including the size and complexity of the tunnel, fire safety regulations, risk assessment, and the specific hazards associated with the environment.